Eyematics Core Data Set
2025.0.0-alpha - ci-build Unknown region code '276'

Eyematics Core Data Set - Local Development build (v2025.0.0-alpha) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: IOP-Methods (Experimental)

Official URL: https://eyematics.org/fhir/eyematics-kds/ValueSet/iop-method Version: 2025.0.0-alpha
Draft as of 2025-01-15 Computable Name: VS_IOP_Method

Describes the various methods of capturing IOP (Intraocular Pressure)

References

Logical Definition (CLD)

Generated Narrative: ValueSet iop-method

This value set includes codes based on the following rules:

 

Expansion

ValueSet

Expansion from tx.fhir.org based on:

This value set expansion contains 19 concepts.

CodeSystemDisplay (und)Definition
  252803002http://snomed.info/sctApplanation tonometry
  252804008http://snomed.info/sctPneumatic tonometry
  252833009http://snomed.info/sctExtended tonometry
  252835002http://snomed.info/sctExtended tonometry - office hours
  252836001http://snomed.info/sctExtended tonometry - 24 hours
  389149000http://snomed.info/sctSchiotz tonometry (procedure)
  389150000http://snomed.info/sctNon-contact tonometry (procedure)
  389151001http://snomed.info/sctPerkins applanation tonometry (procedure)
  389152008http://snomed.info/sctGoldmann applanation tonometry (procedure)
  392338001http://snomed.info/sctIndentation tonometry (procedure)
  1286870002http://snomed.info/sctRebound tonometry (procedure)
  1286871003http://snomed.info/sctMackay-Marg tonometry
  1286902005http://snomed.info/sctDynamic contour tonometry (procedure)
  1286906008http://snomed.info/sctCorneal compensated tonometry using ocular response analyzer (procedure)
  1286913008http://snomed.info/sctOcular response analyzer tonometry - Goldmann-correlated
  1286917009http://snomed.info/sctDigital tonometry
  1286918004http://snomed.info/sctPortable electronic applanation tonometry (procedure)
  rebound-tonometry-remotehttps://eyematics.org/fhir/eyematics-kds/CodeSystem/iop-methods

Rebound tonometry remote

  contact-lens-tonometryhttps://eyematics.org/fhir/eyematics-kds/CodeSystem/iop-methods

Contact lens tonometry


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code