Eyematics Core Data Set
2025.0.0-alpha - ci-build Unknown region code '276'

Eyematics Core Data Set - Local Development build (v2025.0.0-alpha) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Artifacts Summary

This page provides a list of the FHIR artifacts defined as part of this implementation guide.

Structures: Resource Profiles

These define constraints on FHIR resources for systems conforming to this implementation guide.

Intraocular Pressure

A measurement of a patient's intraocular pressure (in mmHg).

Macular Edema

An observation determining the presence or absence of macular edema in the retina.

Ophthalmic Observation Base Profile

This is a profile as a common ground for all the other profiles, so it should not be used directly.

Optic Disc Diameter

Optic disc diameter measured via OCT.

Papill Edema

An observation determining the presence or absence of papilledema (swelling of the optic disc).

RNFL Thickness

Retinal nerve fiber layer thickness measured via OCT.

Retinal Thickness

Retinal thickness measured via OCT.

Retinal Vasculitis

An observation determining the presence or absence of retinal vasculitis.

SUN Classification

Standardization of uveitis nomenclature

Tyndall

Tyndall effect as seen during slit-lamp examination

Visual Acuity (VA)

An assessment of a patients ability to see

Structures: Extension Definitions

These define constraints on FHIR data types for systems conforming to this implementation guide.

Do not perform

If true indicates that the request is asking for the specified action to not occur.

LensDuringVATestSpecification

Specification any Lens that was n front of an eye during a Visual Acuity test test

Terminology: Value Sets

These define sets of codes used by systems conforming to this implementation guide.

Eye.Laterality

Describes which eye of the patient was analyzed

IOP-Code

Codes that describe

IOP-Methods

Describes the various methods of capturing IOP (Intraocular Pressure)

Macular OCT Thickness Map

A value set representing the various subfield thickness measurements of the macula obtained through OCT.

Performed-NotPerformed

A value set representing the status of a procedure or action, indicating whether it has been performed or not.

Retinal nerve fiber layer OCT Thickness Map

A value set representing the various thickness measurements of the retinal nerve fiber layer (RNFL) obtained through OCT.

SUN Grades

ValueSet of the allowed values for the Standardization of uveitis nomenclature (SUN)

Tyndall Grades

ValueSet of the allowed values for the Tyndall effect

Used-NotUsed

A value set representing the status of a device, indicating whether it has been used or not.

VA-Lens-Types

This ValueSet includes codes representing different types of lenses used in ophthalmology. It covers contact lenses, eyeglasses and trial lenses.

VA-Methods

Describes the various charts that can be used to assess visual acuity where concept descends from 400912000 (Visual acuity test equipment (physical object))

Visual Acuity Categorial Values

A value set representing categorical values for visual acuity assessments.

Visual Acuity Code

SNOMED or LOINC code

Visual Acuity Correction Methods

Methods of correction used during a visual acuity test.

Visual Acuity Optotypes

A value set representing various optotypes used in visual acuity testing.

Visual Acuity Special Testing Parameters

A value set representing special parameters used in visual acuity testing that go beyond standard acuity measures.

Visual Acuity Test Distance

A value set representing different test distances.

Visual Acuity Units

A value set representing the units of measurement used in visual acuity assessments.

Terminology: Code Systems

These define new code systems used by systems conforming to this implementation guide.

IOP Methods Code System

IOP additional method types

SUN Grades

Grades of the Standardization of uveitis nomenclature

Tyndall Grades

Grades of the Tyndall Effect seen during the slit lamp examination

Visual Acuity Correction Methods

Correction Methods not covered by snomed

Visual Acuity Optotypes

A CodeSystem that includes codes representing optotype used during visual acuity testing, that are not covered by loinc or snomed

Visual Acuity Units